Language
YSC oil consumption test results, |
1. Only compressed air is needed (refrigerant or power is not needed.) |
2. Cooling air volume and temperature are adjustable. |
3. Simple and reliable structure. |
4. Device is set on the hot air exit to reduce the noise. |
5. Include air inlet switch. |
6. No electrical or chemical action. |
7. Effective cooling performance. |
8. Air exit direction is adjustable. |
9. Universal Nozzle is equipped in the air exit. |
10. Magnetic stand is optional. |
11. Prolong the tool life in machining. |
12. Apply for various cooling demands. |
Test Result
Rate of Cool Wind | % | 50 |
Inlet Temperature (30°C) | Pressure Mpa (kgf/cm2) | 0.44(4.4) |
Air Volume (L/min) | 149 | |
Outlet | Air Volume (L/min) | 88 |
Temperature(。C) | -25 | |
Inlet/Outlet | Different Temperature(。C) | 55 |
Hot Air | Temperature(。C) | 51.7 |
Quantity of Heat | Kcal /H | 66 |