Language

Grease Resistant Lubricator

Grease Resistant Lubricator

Grease Resistant Lubricator

YGL-R08

1. Two operation modes as,
     a. Lubrication: The lubricator runs via lubrication time after power-on.
     b. Intermittence:The lubricator runs via intermittent time after power-on.
2. Lubrication and intermittent time can be adjusted.
3. The indicator on the panel can display the operation of the lubricator.
4. The function of fixed pressure for the pressure relief valve can prolong the system life
5. "FEED" key can force the lubricator to function.
ModelYGL-R
  Voltage110V or 220V (Single Phase)
  Consumption Power (W)56
  Output Power (W)25
  Capacity of Terminal OutputDC/AC 250V 3A
  Lubrication Time (second)2-180
  Intermittent Time (minute)0.5-180
  Output BorePT1/4
  Max. Output Pressure Mpa (kgf/cm2)8-10(80-100)
  Output Volume (c.c./ min)Above 13
  Pressure GaugeO
  Cup Capacity (cc)80012002000
  Weight (kg)3.74.65

Note: Because of continuous improvements, above specifications are subject to change without prior notice.